While the CT-DH-3 has many applications, it was primarily developed to be used with CO2 equipment and exhaust type fans. Internal sensors will allow a 7° temperature comfort zone and a 7% humidity (differential) between the time the fans go "Off "and come back "On" again. Temperature or humidity raise will activate the right hand outlets and deactivate the left hand outlets. The CT-DH-3 has an internal relay that automatically switches power from the equipment side to the exhaust side of the unit when either temperature, humidity or both are in excess of the dial settings. Plug the controller into 110V wall outlet. Set the temperature and humidity to the desired settings. The left or equipment side of the controller is normally in the "On" position and is able to activate CO2 equipment if needed. Equipment to be used for CO2 generation should be plugged into the left outlet. All equipment needed to exhaust the growing area should be plugged into the right outlet which is the exhaust side of the controller. The left outlet (CO2) is defeated whenever the exhaust outlet is activated. See optional thermostat sensors. Also available with built in photo sensor to defeat equipment (left) outlet during darkness periods. Indicate this option with a "P". (CT-DH-3P) Operates on 120VAC with 12 amp switching capacity.



Availability: Usually ships in 2-3 business days.

CT-DH-3 Atmospheric Climate Controller—Dual-outlet control of CO2 & Ventilation AC603padpad

pad
AC605 - CT-DH-3P Same as above W/photo sensor for lights on operation onlypadThe CT-DH-3P is installed for cooling and dehumidifying control. This unit may be used independently or with many other Green Air Products controls to create an integrated system. This diagram shows how to install the CT-DH-3P for exhaust fan control with synchronized CO2 enrichment. When the temperature or humidity raise above the predetermined setting, the CT-DH-3P initiates a venting cycle and CO2 generation is momentarily halted. The Cyclestat is used to time the frequency and duration of the CO2 production. In the event of an exhaust cycle the Cyclestat will reset and immediately replenish CO2 enrichment apon completion of the exhaust function. The CT-DH-3P has a built in photo sensor that prevents CO2 operation during darkness periods.
pad

Availability: Usually ships in 2-3 business days.

AC605 - CT-DH-3P Same as above W/photo sensor for lights on operation only AC605padpad
pad

INTERIOR GARDENS

2727 Lyndale Ave. S.

Minneapolis, MN. 55408

Order Line: 1-800-498-4178

Office: 1-612-870-9077

Fax: 1-612-870-8901

[email protected]